[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f2eZSX4BXDa6qdMHrAtz_nWV4EAOaybc4ONSqmEbZu1A":3},{"success":4,"post":5},true,{"id":6,"title":7,"slug":8,"content":9,"excerpt":10,"category":11,"tags":12,"author":13,"cover_image":14,"status":15,"comment_enabled":4,"views":16,"created_at":17,"updated_at":18},65,"盾构管片拉筋布筋介绍","post-65","本文章为盾构管片钢筋模块对S4筋的布置\n\n查看S4筋详情，生成三维视图，并点击显示相关钢筋\n\n![image-20260626145323251](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518554-w8nqx7r.png)\n\n隐藏修改所有钢筋的直径改为20，\n\n![image-20260626145546114](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518564-iafwnp.png)\n\n下图为直径20的效果，现在再改回10\n\n![image-20260626153542755](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518618-e1xeh.png)\n\n然后下面的添加S4筋、删除S4筋还有查看单根S4筋，都在这个钢筋布置图截面里面进行操作\n\n![image-20260626145914771](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518567-ljhua.png)\n\n首先打开这个截面图\n\n![image-20260626145943204](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518569-bew2kn.png)\n\n点击删除选中需要删除的钢筋\n\n![image-20260626150153777](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518572-nd2z6x.png)\n\n如果想要添加的话，点击添加，选中这个焦点的圆，回车确定添加\n\n![image-20260626150416779](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518575-oga6fo.png)\n\n重生成S4筋的功能是当添加或删除S4筋的时候\n\n或者修改了其他关联的钢筋\n\n例如对S1、S2和S3筋做了修改\n\n那么S4筋可以点击这个重生成\n\n可以将修改后的钢筋生成出来\n\n![image-20260626150702312](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518577-cencfr.png)\n\n查看单根钢筋，选择比较靠近手孔的钢筋进行查看，并检查其保护层厚度\n\n![image-20260626151019558](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518580-p4ocb.png)\n\n查看可发现它的保护层厚度并没有打架\n\n点击检测\n\n发现满足保护层厚度需求\n\n![image-20260626151047344](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518584-a9diah.png)\n\n查看单根钢筋的xy平面，如下图，可以看到这个s4筋勾住了这个s2筋和s1筋\n\n![image-20260626151114457](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518587-vnuz6.png)\n\n其中这个s1筋靠近了手孔，导致它稍微弯起来了，导致s1筋与其他的s1筋位置有差别\n\n![image-20260626151155252](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518590-880vtk.png)\n\n返回S4筋，可以点击查看所有的S4筋的保护层情况\n\n![image-20260626151230521](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518592-vmkwgr.png)\n\n可以看到绝大部分S4筋都满足保护层厚度需求\n\n![image-20260626151302239](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518594-gcxx3d.png)\n\n查看这个不满足的S4-95\n\n![image-20260626151322296](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518597-bxj9ux.png)\n\n查看其保护层，发现它与手孔打架，如下图：\n\n![image-20260626151627688](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518600-ijbsb.png)\n\n这个就没办法修改了，可以直接删掉这个S4-95\n\n![image-20260626151719706](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518605-n72iwe.png)\n\n看图形应该是这里    删除后重新生成\n\n![image-20260626152620710](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518609-qce423.png)\n\n再点击一下检测保护层厚度，查看S95发现 因为删除了钢筋重新编号，原来S4—95不存在了\n\n![image-20260626152714755](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518612-bjlnp.png)\n\n所以现在的S95已经满足了保存厚度需求\n\n![image-20260626152745606](\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518615-2y9pn2.png)","本文章为盾构管片钢筋模块对S4筋的布置\n\n查看S4筋详情，生成三维视图，并点击显示相关钢筋\n\n!image-20260626145323251\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F1782460518554-w8nqx7r.png\n\n隐藏修改所有钢筋的直径改为20，\n\n!image-20260626145546114\u002Fuploads\u002Fposts\u002F65\u002Fcontent\u002F17824605...","shield",[],"Admin","\u002Fuploads\u002F2026\u002F06\u002F1782460628951-umiio.png","published",26,"2026-06-26 07:55:18","2026-06-26 07:57:15"]